Fire alarm and sprinkler permits live or die on the submittal package — device cutsheets, drawings, and calculations complete and consistent before the city ever sees them. We assemble, check, and file your package, then track plan check and handle corrections until the permit is issued to your team.
Fire Alarm Permit Submittals
New systems and alterations: FACP replacements, device additions, tenant-improvement tie-ins, and monitoring changes.
What we need from you (after your signed authorization letter and photo ID):
- Fire alarm drawings — floor plans with device layout, riser diagram, ceiling heights/reflective ceiling plan
- CSFM-listed cutsheets for every device: panel, smoke/heat detectors, pull stations, notification appliances, control/monitor modules, annunciators
- Battery calculations and voltage-drop calculations
- Sequence of operations / input-output matrix
- For alterations: existing panel make/model and the approved prior drawings if you have them
- Your C-10 or C-16 license number (stated on the authorization letter)
Fire Sprinkler Permit Submittals
New systems and alterations: tenant improvements, head relocations/adds, new risers, and underground fire service.
What we need from you:
- Sprinkler drawings — layout, riser diagram, hydraulic calculation area and remote area
- Hydraulic calculations
- Water supply information (recent flow test, if available)
- Cutsheets: sprinkler heads, valves, backflow preventer, fire department connection
- Underground (when in scope): pipe, trench, and thrust-block details
- Your C-16 license number (stated on the authorization letter)
Component Guides and the Spec Library
Device-level guides from the desk — what each component is, when it pulls a permit, and the cutsheet and listing package reviewers ask for:
- Duct detector permits — the device that lives on two sets of drawings
- ERRCS permits — public safety DAS approval, UL 2524, witnessed grid testing
- Speaker strobe permits — candela, taps, and the listings reviewers check
The spec library — manufacturer specs paired with the California listing path and the permit path:
- Notifier FSP-951 — data sheet DN-60977, CSFM listing 7272-0028:0503
- System Sensor D4120 — the duct detector that files as two products
- System Sensor SPSRL — L-Series speaker strobe specs and listing path
- Fire-Lite BG-12 and MS-Series panels — pull stations and panels, DF- data sheets
Fire district guide: Santa Clara County Fire Department (SCCFD) fire permits — the district's own counter, its cities, and how filings run there.
Call (888) 907-9511